E. Chimney Requirements

When planning your fireplace location, the chimney construc-

tion and necessary clearances must be considered. The fire-

place system and chimney components have been tested to

provide flexibility in construction. The following figures are

the minimum distances from the base of the fireplace.
Minimum overall straight height is 6 ft 4 in. if the fireplace

is freestanding and a minimum of 10 ft from a combustible

structure.

See Figure 3.2.

• Chimney must extend 2 ft (.6 m) above any portion

of the roof within 10 ft (3 m) of the chimney. Refer to

Figure 6.1.

Note: A maximum of two pairs of offsets and returns may

be used.

ft

m

Minimum height width offset/return

16

4.88

Maximum height

90

27.43

• Maximum chimney length between an offset

and return

20

6.1

Maximum distance between chimney

stabilizers

35

10.67

Double offset/return minimum height

24

7.32

Maximum unsupported chimney length

between the offset and return

6

1.83

• Maximum unsupported chimney height above

the fireplace

35

10.67

• Minimum overall straight height if fireplace is

freestanding

6.4

3.048