Caution, Installation of fireplace, Warning – Hearth and Home Technologies MONTANA 42 EN User Manual

Page 12

Advertising
background image

Outdoor Lifestyles by Hearth & Home Technologies Inc. • Montana US-CAN • 4039-156 Rev P • 10/12

12

72 in./183 cm

min.

TR11/TR444

Termination

Cap

A. Install the Dual Cooling Air Kit

The cooling air kit is supplied as a standard feature with this

fireplace and is required for safe operation. Installation must

be done at the time of initial construction. The cooling air in-

let tubes must be a minimum of 72 in. (1829 mm) above the

base of the fireplace to prevent potential blockage by snow

or yard debris. See Figure 4.1.
To install the air kit collar, slide one of the tabs down into the

seam. See Figure 4.2. Secure the collar tabs to the fireplace

with screws placed into the holes provided. See Figure 4.3.
Repeat for other side.

Sharp Edges

• Wear protective gloves and safety glasses

during installation.

CAUTION

4

Installation of Fireplace

Fire Risk

Asphyxiation Risk

Do not draw outside combustion air from:

• Wall, floor or ceiling cavity.

• Enclosed space such as an attic or

garage.

• Close proximity to exhaust vents or

chimneys.

Fumes or odor may result.

WARNING

Figure 4.1 Cooling Air Location

Figure 4.2 Slide the Tabs

Figure 4.3 Secure the Tabs

Note: The cooling air kit must terminate at least 6 ft. (1.83 m)

above ground level.

11-10 in./279-254 mm

adapter not shown