Caution, Warning, Chimney assembly – Hearth and Home Technologies MONTANA 42 EN User Manual

Page 14: A. chimney requirements, Table 5.1

Advertising
background image

Outdoor Lifestyles by Hearth & Home Technologies Inc. • Montana US-CAN • 4039-156 Rev P • 10/12

14

A. Chimney Requirements

Vertical distances are measured from the base of the fire-

place.
Minimum overall straight height is 6 ft 4 in. if the fireplace

is freestanding and a minimum of 10 ft from a combustible

structure.

See Figure 3.2.

• Chimney must extend 2 ft (.6 m) above any portion

of the roof within 10 ft (3 m) of the chimney. Refer to

Figure 6.1.

To determine the chimney components needed to complete

your particular installation, follow the steps below:
• Determine the total vertical height of the fireplace

installation. This dimension is measured from the base of

the fireplace assembly to the point where the smoke exits

the termination cap.

• Subtract the effective height of the fireplace assembly from

the overall height of the fireplace installation (measured

from the base of the fireplace to the bottom of the

termination cap).

• Refer to Table 5.1 to determine what components must

be selected to complete the fireplace installation.

• Determine the number of ceiling firestops, stabilizers,

roof flashing, etc. required to complete the fireplace

installation.

Table 5.1

• Do NOT connect this fireplace to a chimney flue

servicing another appliance.

• Do NOT connect to any air distribution duct or

system.

CAUTION

Fire Risk

• Must maintain 2 in. (51 mm) air clearance

to insulation and other combustible

materials.

WARNING

Note: A maximum of two pairs of offsets and returns may

be used.

5

Chimney Assembly

ft

m

Minimum height width offset/return

16

4.88

Maximum height

90

27.43

• Maximum chimney length between an offset

and return

20

6.1

Maximum distance between chimney

stabilizers

35

10.67

Double offset/return minimum height

24

7.32

Maximum unsupported chimney length

between the offset and return

6

1.83

• Maximum unsupported chimney height above

the fireplace

35

10.67

• Minimum overall straight height if fireplace is

freestanding

6.4

3.048

HEIGHT OF CHIMNEY COMPONENTS

in.

mm

US

Canada ONLY

Chimney Stabilizer

SL11

SL4

4-3/4

121

Ceiling Firestops

FS538

FS538

0

0

FS540

FS540

0

0

Offsets/Returns

SL1130

SL430

14-1/2

368

Chimney Sections*

SL1106

SL406

4-3/4

121

SL1112

SL412

10-3/4

273

SL1118

SL418

16-3/4

425

SL1136

SL436

34-3/4

883

SL1148

SL448

46-3/4

1187

n/a

SLA10

16-3/4

425

* Dimensions reflect effective height.

Advertising