Note: To protect against the effect of corrosion on those

parts exposed to the weather, the termination cap can be

painted with a rust-resistant paint.

Fire Risk

• The minimum overlap of cap to pipe

MUST be met or chimney may separate

from cap.

Separation allows sparks, heat and embers

to escape.

WARNING

C. Install the Termination Cap

Install the chimney sections up through the chase enclosure

and refer to termination cap instructions.

Storm

Collar

Chimney

Pipe

Chase Top

Termination

Cap

Chase

6 in. (153 mm)

Minimum top of

chase to top of

chimney pipe

Collar

2 in. (51 mm)

Minimum Height

Do NOT

block air holes

Caulk gaps between

storm collar & pipe,

and storm collar

& chase top.

Termination cap pipe and chimney section must be snapped

together to maintain an overlap of 1-1/2 in. (38 mm).

Slip

storm collar

around chimney pipe

before termination

cap pipe is snapped

into the chimney

pipe.

Figure 6.4 Installing a TR11/TR444 Round Termination Cap

• TR11/TR444 Round Termination Cap

Storm

Collar

Chimney

Pipe

Chase Top

Termination

Cap

Chase

14 1/2 in. (368 mm)

Maximum

Collar

2 in. (51 mm)

Minimum Height

Caulk gaps between

storm collar & pipe,

and storm collar

& chase top.

Do NOT

block air

holes

3 clip brackets.

Slip over chase collar

and attach with screws

provided.

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)

Assemble

storm collar

around extended

termination cap

pipe

once cap is

installed.

• TR11T/TR442 Round Telescoping Termination Cap

Figure 6.5 Installing a TR11T/TR442 Round Telescoping Termina-

tion Cap

Chimney

Pipe

Chase Top

Termination Cap

Chase

Collar

2 in. (51 mm)

Minimum Height

Place waterproof

caulk or sealer under

each flange of the

termination cap and

on top of each screw

to help prevent leaks.

Flange

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)

2 in. (51 mm)

maximum

4 3/4 in. (121 mm)

maximum

The last section of pipe

must stop between 2 in. (51

mm) above the top of the

chase and 4 3/4 in. (121

mm) below the top of the

chase.

• ST1175/ST475 Square Termination Cap

Figure 6.6 Installing an ST1175/ST475 Square Termination Cap