8

LISTED

TERMINATION CAP

LISTED

TERMINATION CAP

LISTED SINGLE-WALL
GAS VENT

LISTED SINGLE-WALL
GAS VENT

NON-COMBUSTIBLE
CONSTRUCTION

NON-COMBUSTIBLE
CONSTRUCTION

B-TYPE
VENT

B-TYPE
VENT

MINIMUM VERTICAL RISE = 9FT

MAXIMUM HORIZONTAL RUN = 15FT

V:H = 2:1

NOTE: The vent termination must be in a

vertical position and the termination cap must

be listed for the vent pipe used.
Consult Local Building Code Officials and Codes for

proper vent system installations.

WARNING: THIS GAS FIREPLACE

MUST NEVER BE VENTED BY

CONNECTING TO A CHIMNEY FLUE

SERVING A SEPARATE SOLID FUEL

BURNING APPLIANCE.

Figure 5. Vent System Attachment