Figure 2. Fireplace Dimensions, Locations, and

Space Requirements

Clearance Requirements

The top, back, and sides of the fireplace are defined

by stand-offs.

Minimum Clearances from the Fireplace to

Combustible Materials

Glass

Back of

Sides of

Top of

Front

Floor

Fireplace

Fireplace

Fireplace

Ceiling

36 inches

0

1/2 inch

1/2 inch

3

1/2

inches (89mm) 31 inches

(914 mm)

(13 mm)

(13 mm)

(787 mm)

The minimum clearance to a perpendicular wall extending

past the face of the fireplace is one inch (25mm).
The minimum clearance from the top face of the fireplace

to combustible finishing materials such as drywall, is one

inch (25mm).
The back of the fireplace may be recessed 21 1/2

inches (546mm) into combustible construction.
Minimum Clearances from the B-Type Vent

Pipe to Combustible Materials is 1 inch (25mm)

all around the pipe.

MODELS

A

B

C

D

E

8000TVC

49

22

39 1/2

56

79

Step 1

Locating the

Fireplace

The diagram below shows space and clearance

requirements for locating a fireplace within a room.