Step 8 gas pressure requirements – Heat & Glo Fireplace Heat & Glo Fireplace 8000TVC User Manual

Page 16

Advertising
background image

13

• At the gas line access hole, use insulation to re-

pack the space around the gas pipe.

• Insert insulation from the outside of the fireplace and

pack the insulation tightly to totally seal between the

pipe and the outer casing.

The gas line should be

installed by a qualified

service technician.

Figure 9. Gas Supply Line

Step 8

Gas Pressure

Requirements

Pressure requirements for Heat-N-Glo gas fireplaces

are shown in the table below.

Pressure

Natural Gas

Propane

Minimum

5.0 inches

11.0 inches

Inlet Pressure

w.c.

w.c.

Maximum Inlet

14.0 inches

14.0 inches

Gas Pressure

w.c.

w.c.

Manifold

3.5 inches

10.0 inches

Pressure

w.c.

w.c.

The tap for the manifold and inlet pressures are on the

face of the gas control valve. Remove the control

panel covering the valve. Use a small screwdriver to

crack open the screw in the center of the tap. Position

a rubber hose over the tap to obtain the pressure

reading.
The fireplace and its individual shut-off valve must be

disconnected from the gas supply piping system

during any pressure testing of the system at test

pressures in excess of one-half (1/2) psig (3.5 kPa).
The fireplace must be isolated from the gas supply

piping system by closing its individual shut-off valve

during any pressure testing of the gas supply piping

system at test pressures equal to or less than one-half

(1/2) psig (3.5 kPa).