For direct spark ignition (dsi) wiring, Caution, 15 figure 11. fan wiring diagram – Heat & Glo Fireplace Heat & Glo Fireplace 8000TVC User Manual

Page 18

Advertising
background image

15

Figure 11. Fan Wiring Diagram

For Direct Spark Ignition (DSI) Wiring

Appliance Requirements

This appliance requires that 110-120 VAC be wired to

the junction box included in the manual bag assembly.

Maintain correct polarity when wiring the junction box.

The junction box is installed by sliding one tab of the box

through the slot on the lower right side of the outer wrap

and driving a screw through the other tab into the pilot

hole on the outer wrap.
Optional Accessories

Optional fan and remote control kits require that 110-120

VAC be wired to the fireplace junction box.
Remote Wall Switch

Position the remote wall switch in the desired position

on a wall. Run a maximum of 25 feet (7.8 m) or less of

16 A.W.G. minimum wire and connect it to the fireplace

ON/OFF switch pigtails.

NOTE

Electrical wiring must be installed by a licensed electrician.

CAUTION

LABEL ALL WIRES PRIOR TO DISCONNECTION

WHEN SERVICING CONTROLS. WIRING ERRORS

CAN CAUSE IMPROPER AND DANGEROUS

OPERATION. VERIFY PROPER OPERATION

AFTER SERVICING.

NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105 DEGREE C
RATED WIRE.

NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105 DEGREE C
RATED WIRE.

BLOWER

BLOWER RECEPTACLE

JUNCTION BOX

VARIABLE SPEED CONTROL

TEMPERATURE
SENSOR SWITCH

TEMPERATURE
SENSOR SWITCH

GROUND

WHT

BLK

BLK

GRN

WHT

BLK

BLK

BLK

BLK

BLK

BLK

BLK

110-120 VAC

BLK

WHT

FAN WIRING DIAGRAM

(Located on right

side of firebox)

Advertising