Step 6 the gas control systems – Heat & Glo Fireplace Heat & Glo Fireplace 8000TVC User Manual

Page 13

Advertising
background image

10

Step 5

Positioning,

Leveling, and

Securing the

Fireplace.

Standing Pilot Ignition System

This system includes millivolt control valve, standing

pilot, thermopile/thermocouple flame sensor, and

piezo ignitor.

WARNING

110-120 VAC MUST NEVER BE

CONNECTED TO A CONTROL VALVE

IN A MILLIVOLT SYSTEM.

Direct Spark Ignition (DSI) System

The DSI system includes a 120V control valve,

electronic module, and spark ignitor/flame sensor.

WARNING

CONTINUOUS 110-120 VAC SERVICE

MUST BE WIRED TO THE FIREPLACE

JUNCTION BOX IN A DSI SYSTEM.

The diagram below shows how to properly position,

level, and secure the fireplace.

1. Place the fireplace

into position.

2. Level the fireplace

from side to side and

from front to back.

3. Shim the fireplace

with non-combustible

material, such as

sheet metal, as

necessary.

4. Secure the fireplace

to the framing by

nailing or screwing

using the nailing tabs.

Figure 7. Proper Positioning, Leveling, and

Securing of a Fireplace

Step 6

The Gas Control

Systems

WARNING

THIS UNIT IS NOT FOR USE WITH

SOLID FUEL.

Two types of gas control systems are used with these

models: Standing Pilot Ignition and Direct Spark

Ignition (DSI).

WARNING:

To ensure proper

clearances the front

framing header must be

installed on its narrow

edge and to the front of

the frame.

NOTE:

Non-combustible material

that is supplied with unit is

not shown for clarity.