6

Air Damper
Before lighting the burner, open the damper. Close

the damper when the burner is off.
Detailed installation instructions for Model AK-TV

Outside Air kit are found in the kit.

Figure 4. Make-up Air

vented gas fireplaces with draft hoods, to draft

properly. If the home experiences negative pressure

or is likely to experience negative pressure,

connection to an outside air source is mandatory.
Installing Optional Outside Make-up Air:

This unit is equipped to accept outside air. By using

outside make-up air, the amount of room air used for

combustion will be reduced. It is recommended that

an AK-TV air kit be used with this appliance.

WARNING: IN A NEGATIVE PRESSURE

CONDITION (LIKELY TO OCCUR IN

NEW HOMES THAT DO NOT HAVE ADEQUATE

MAKE-UP AIR) THE OUTSIDE AIR KIT MUST

BE INSTALLED TO OBTAIN PROPER

PERFORMANCE AND TO HELP PREVENT

SPILLAGE OF COMBUSTION GASES.

A 4-inch side collar/damper (found in AK-TV Kit)

must be installed on the fireplace by attaching the

side collar to the outer wrap of the fireplace at the

right-hand rear corner using sheetmetal screws.

See Figure 4. Attach one end of a 4-inch flexible air

duct (not provided in the AK-TV Kit) to the side collar

and the other end of the duct to the make-up air

termination cap. Use plastic tie straps to secure the

ends of the flex duct to each collar.