14

NOTE: Electrical wiring must be installed by a

licensed electrician.
Caution: Disconnect remote controls if you

are absent for extended time periods. This

will prevent accidental fireplace operation.

For Standing Pilot Ignition Wiring

Appliance Requirements

• This appliance DOES NOT require 110-120

VAC to operate.

WARNING

DO NOT CONNECT 110-120 VAC TO

THE GAS CONTROL VALVE OR THE

APPLIANCE WILL MALFUNCTION AND

THE VALVE WILL BE DESTROYED.

Optional Accessories

Optional fan and remote control kits require that 110-

120 VAC be wired to the factory installed junction

box before the fireplace is permanently installed.
Remote Wall Switch

Position the remote wall switch in the desired

position on a wall. Run a maximum of 25 feet (7.8

m) or less length of 18 A.W.G. minimum wire and

connect it to the fireplace ON/OFF switch pigtails.

WARNING: DO NOT CONNECT 110-120

VAC TO THE REMOTE WALL SWITCH

OR THE CONTROL VALVE WILL BE

DESTROYED.

CAUTION

LABEL ALL WIRES PRIOR TO DISCONNECTION

WHEN SERVICING CONTROLS. WIRING

ERRORS CAN CAUSE IMPROPER AND

DANGEROUS OPERATION. VERIFY PROPER

OPERATION AFTER SERVICING.

Figure 10. Standing Pilot Ignition Wiring Diagram