HP 20/700 User Manual

Page 174

Advertising
background image

Appendix A

DLT Drives and Tape Cartridges 173

Appendix A

Table 10

DLT Cleaning Light Issues

DLT Cleaning Light Issues

DLT Cleaning Light Issues

DLT Cleaning Light Issues

Cause

Cause

Cause

Cause

Solution

Solution

Solution

Solution

Contamination by loose debris

Avoid by ensuring the drive is operated in a clean, contamination-

free environment. Cartridges should be stored vertically in their

plastic cases.

Contamination by head staining.

(Caused by adhesion of chemicals

that are present in the tape media

to the head surface.)

One or two passes with a cleaning tape should resolve cleaning

lights caused by normal head staining. If a cleaning tape is

unsuccessful in resolving a cleaning light after 3 or more attempts,

the cleaning tape may be contaminated, and should NOT be used

in another drive

Temperature and humidity

Tapes should be stored and used in the middle of the temperature

and humidity specifications range of 64-79° F, and 40-60% RH.

Non-acclimated media

A tape should be acclimated for a minimum of 24 hours before

being used, particularly if it has been stored at a substantially

different temperature or level of humidity than the tape library.

Wrong cleaning cartridge

Only use the cleaning cartridge specifically designated for each

drive type (see

page 170

).

Wrong tape format

Attempting to load, read, or write tapes that were written in other

formats can cause cleaning lights.

Abnormal build up of head

debris. (Frequent load/unload

operations with minimal tape

reading or writing can cause this

condition.)

Do not perform frequent load/unloads without also doing tape

operations.

Bad/defective/contaminated

media

If a cleaning light is cleared using a cleaning tape, and then

immediately reappears when a particular cartridge is reloaded,

that cartridge should be suspected as being contaminated.
If this occurs, re-clean the drive, loading a known good tape. In

rare cases, a tape cartridge can be worn out, have bad calibration

tracks, or have a bad tape directory recorded by another drive.
Any cartridge that is suspected of being defective or contaminated

should NOT be reused in any drive.

Expired cleaning cartridge

A cleaning cartridge is good for 20 uses. After that, the library

status screen will display EXPIRED.

Cleaning requested/required and

overuse of cleaning cartridges

Use of a cleaning cartridge should only be done when the library

status screen states CLEAN NEEDED.

Old firmware revisions

If a cleaning tape does not resolve a cleaning light issue, make

sure the latest drive firmware is being used.

Advertising