CB1200-I Pellet Insert

Mark area of
floor to cut

Starter hole

Keep sharp edge of
metal floor away from
power cord

• The firebrick (refractory), glass doors, screen rails,

screen mesh and log grates can be removed from a
factory-built firebox in order to gain minimum insert
opening requirements.

• Any smoke shelves, shields and baffles may be

removed from a factory-built firebox if attached with
mechanical fasteners.

• The metal floor of the factory-built firebox may be

removed to facilitate the installation of the insert only
when a 1 inch (25mm) airspace is provided between
the insert and the floor of outer wrap.

If the floor is made of thin metal, we recommend using

a Quarda-Fire floor protector, Part 811-0730, which is
available through your dealer.

Figure 11.1. Measure and mark the metal
floor for cutting. With a drill, make a starter
hole in each corner.

Figure 11.2. Using a saws-all, cut out the
floor.

Figure 11.3. Place the insert into the fac-
tory-built firebox. Ensure that the power
cord can not be damaged by the sharp metal
edge. You may need to cut out a notch to
accommodate the cord.

H. Removing Metal Floor of Factory-Built

Firebox