CB1200-I Pellet Insert

A

B

C

D

D. Minimum Opening for Masonry and Zero

Clearance Fireplaces for Built-In Using
Rear Shroud

SIDE

W

A

L

L

MANTEL

D

C

E

A

B

Face Trim

Inches

Millimeters

A

Louvers to combustible
side wall

6

153

B

Insert top to mantel

12

305

C

Top to Face Trim

3

76

D

Hearth Extension - Front

6

153

E

Hearth Extension - Sides

8

203

Inches

Millimeters

A

Rear Width

22

558

B

Depth

15-1/2

393

C

*

Height - Top Vent

25-1/2

647

Height - Rear Vent

22-1/2

571

D

Front Width

29-1/4

743

Figure 9.1

Figure 9.2

C. Minimum Clearances To Combustibles for

Masonry and Zero Clearance Fireplaces

*

The size of your floor protector choice must be

added to this dimension. If using Quadra-Fire floor
protector, Part 811-0730, allow 1-1/2” (38mm).

NOTE: A Quadra-Fire floor protector (Part 811-0730) is
available through your dealer to be used as a floor protector
for the section under the insert body only. Floor protection
to front and sides of insert unit must be supplied in addition
to this part.