CB1200-I Pellet Insert

C. Full Reline With Outside Air

Figure 15.1

Outside Air
Termination

at

Chimney Top

Outside Air
through
Rear Wall

Exit through the

Ash Clean-Out of

Masonry Chimney

12” (305mm)
min. below

12” (305mm)
min. above

NOTE; Use metal
plate around
exhaust vent pipe
and seal all edges
with non-flammable
insulation such as
fiberglass, mineral
wool or ceramic.

Do not use high
temperature caulk-
ing materials to seal
any edge to prevent
future serviceability

NOTE: Check clearances carefully for this
type of installation to ensure adequate room
for outside air venting.

Check building codes prior to installation.
• Installation MUST comply with local, regional,

state and national codes and regulations.

• Consult local building, fire officials or authorities

having jurisdiction about restrictions, installa-
tion inspection, and permits.

CAUTION

NOTE: In Canada, only a full reline is
allowed per ULC S-628, ORD ULC C1482.