Service Calibrations

5-3

HP DesignJets 1050C and 1055CM Printers Service Manual

Service Calibrations

The following is a list of all internal service calibrations available in
the Printers. Instructions for entering the service calibrations menu
are given on Page 5-4.

1 Accuracy Calibration

Page 5-6

The purpose of this Service Calibration is to calibrate the nominal
advance of the media. This calibration is necessary to control the
exact movement of the media in order to avoid print quality
problems like banding.

2 Line Sensor

Page 5-9

The purpose of this Service Calibration is to calibrate the intensity
of the line sensor in the Carriage PCA. An incorrect calibration can
result in edge-detection failures during media loading and incorrect
reading of prints that are used for alignment or calibration.

3 Service Station

Page 5-11

The purpose of this Service Calibration is to calibrate the Service
Station in relation to the Carriage Assembly.

4 Roller Mark Position

Page 5-13

The purpose of this Service Calibration is to calibrate the Mark
Encoder which is located on the Drive Roller.

5 Pen to Paper Spacing

Page 5-15

THIS CALIBRATION IS NO LONGER REQUIRED.

6 Color to Color Calibration

Page 5-16

The purpose of this Service Calibration is to correct the alignment
between the Printheads and the rest of the Printer. This calibration is
necessary in order to prevent color misalignment.

7 Calibrations Backup

Page 5-19

The purpose of this Service Calibration is to allow the EEROM
contents to be saved when the Electronics Module or the Tubes
System is replaced.

8 Pen Alignment

Page 5-22

The purpose of this Service Calibration is to correct the alignment
between the Printheads. This calibration is necessary in order to
prevent color misalignment and print quality defects like banding.

u

Carriage Height Calibration

Page 5-24

The purpose of this Service Calibration is to adjust the distance
between the Carriage and the Center Platen. This calibration is
necessary in order to prevent problems like Printhead crashes.