Service Tests and Utilities

4-18

HP DesignJets 1050C and 1055CM Printers Service Manual

2 The test will start and the following message will appear on the

front panel:

3 Once the test is completed, the following message will appear on the

front panel:

4 Press Enter and the following message will appear on the front

panel:

To check if the values displayed after the test are within the limits,
refer to the following table:

SCAN AXIS

Running Scan

Axis Test...

(takes 2mn...)

SCAN AXIS FORWARD

Avg PWM: XXX
Max PWM: XXX
Stabilizat Dist: XXXX
Avg speed offset: XXX
STD speed offset: XXX

SCAN AXIS BACKWARDS

Avg PWM: XXX
Max PWM: XXX
Stabilizat Dist: XXXX
Avg speed offset: XXX
STD speed offset: XXX

Scan-Axis Forward

Scan-Axis Backwards

Normal

Maximum

Normal

Maximum

Avg. PWM

165

185

-165

-185

Max. PWM

220

240

220

240

Stabilize Dist.

1800

2400

1800

2400

Avg. Speed offset

2.4

10

2.4

10

STD Speed offset

4.4

10

4.4

10