HP 1055CMHP User Manual
Page 92

Service Tests and Utilities
4-18
HP DesignJets 1050C and 1055CM Printers Service Manual
2 The test will start and the following message will appear on the
front panel:
3 Once the test is completed, the following message will appear on the
front panel:
4 Press Enter and the following message will appear on the front
panel:
To check if the values displayed after the test are within the limits,
refer to the following table:
SCAN AXIS
Running Scan
Axis Test...
(takes 2mn...)
SCAN AXIS FORWARD
Avg PWM: XXX
Max PWM: XXX
Stabilizat Dist: XXXX
Avg speed offset: XXX
STD speed offset: XXX
SCAN AXIS BACKWARDS
Avg PWM: XXX
Max PWM: XXX
Stabilizat Dist: XXXX
Avg speed offset: XXX
STD speed offset: XXX
Scan-Axis Forward
Scan-Axis Backwards
Normal
Maximum
Normal
Maximum
Avg. PWM
165
185
-165
-185
Max. PWM
220
240
220
240
Stabilize Dist.
1800
2400
1800
2400
Avg. Speed offset
2.4
10
2.4
10
STD Speed offset
4.4
10
4.4
10