HP DesignJets 1050C and 1055CM Printers Service Manual

7. Calibrations Backup

The purpose of this Service Calibration is to allow the EEROM
contents to be saved when the Electronics Module or the Tubes
System has been replaced.

WARNING

ALWAYS PERFORM THE CALIBRATIONS BACKUP
AFTER REPLACING THE ELECTRONICS MODULE OR
THE TUBES SYSTEM.

Perform the Calibrations Backup as follows:

1 In the Service Utilities submenu, scroll to "7. Calibrations Backup"

and press Enter.

2 When the following message appears on the front panel, you must

select which component you have replaced. Select either the
Electronics Module or Tubes System and press Enter.

If the Electronics Module was replaced

a If the Electronics Module was replaced, then select Electronics Module

and press Enter.

b The following message will appear asking you to confirm the operation.

Select ACCEPT if you want to continue the Calibrations Backup, or select

Top

Enter

Back


Press Enter

Make Selection

Service Calibrations

4. Roller mark position...

5. Pen to Paper Spacing...

6. Color to Color cal...

8. Pen Alignment...

7. Calibrations backup...

CALIBRATIONS BACKUP

What have you
replaced?

Tubes replaced...

Electronics Module repl

Top

Enter

Back