Configuring DIP Switches

2-11

If the NV SEL DIP switch is:

ON (enabled)

– The Edge Router module uses configuration settings

stored in its NVRAM. If NVRAM does not contain configuration settings, the

Edge Router modules are assigned to the Isolate_1 network.

OFF (disabled)

– The Edge Router module uses DIP switch settings.

Selecting a Network

In an unmanaged ONcore hub, the DIP switches determine the network

setting (unless NVRAM configuration settings are enabled).

1

To select a network:

Set the switches according to Table 2-5.

Switch combinations not listed in Table 2-5 select Isolate_1.

2

Disable NVRAM by setting the NV SEL DIP switch to the off position.

Table 2-5

ONcore Network Selection DIP Switch Settings

Network

Selection

Switch Settings

CH SEL 0

CH SEL 1

CH SEL 2

CH SEL 3

Ethernet_1

(default)

ON

ON

ON

ON

Ethernet_2

OFF

ON

ON

ON

Ethernet_3

ON

OFF

ON

ON

Ethernet_4

OFF

OFF

ON

ON

Ethernet_5

ON

ON

OFF

ON

Ethernet_6

OFF

ON

OFF

ON

Ethernet_7

ON

OFF

OFF

ON

Ethernet_8

OFF

OFF

OFF

ON

Isolate_1

ON

ON

ON

OFF

Isolate_2

OFF

ON

ON

OFF

Isolate_3

ON

OFF

ON

OFF

Isolate_4

OFF

OFF

ON

OFF