background image

Configuring the Edge Router Engine

3-11

Console and auxiliary port specifications are provided in Table 3-2 and

Table 3-3, respectively.

Mini-DIN connector pinouts are provided in Appendix A.

The Edge Router module is shipped autoconfigured for connection to a

network running NetWare®. If you are not connected to a NetWare network,

you may see the following message:

The IPXNetwork for LocalPath ms_ethernet couldn’t be

learned.

Ignore this message and continue with the appropriate configuration.

Using the Terminal

to Configure the

Edge Router Engine

Edge Router engine documentation is included on the Cisco Systems

CD-ROM that is shipped with the Edge Router module.

Refer to the

Cisco Router Products Configuration and Reference Guide

for

information on configuring parameters for the Edge Router module.

Table 3-2

Console Port Information

Interface

Connector

Transmission

Type

Protocol

RS-232

8-pin mini-DIN

DTE

Asynchronous, 9600, 8-bit data,

1 stop bit, no parity, XON/XOFF

Table 3-3

Auxiliary Port Information

Interface

Connector

Transmission

Type

Protocol

RS-232

8-pin mini-DIN

DTE

Asynchronous or synchronous, 9600,

8-bit data, 1 stop bit, no parity,

XON/XOFF