Correcting operating malfunctions, Correcting, Operating – HP 2103R-CSDI User Manual

Page 65: Malfunctions

Advertising
background image

Correcting Operating Malfunctions

5-5

Correcting

Operating

Malfunctions

Table 5-1 lists the symptoms of operating malfunctions for the Edge Router

module and shows possible causes and corrective actions for these

malfunctions.

Table 5-1

Troubleshooting Malfunctions

Symptom

Possible Cause

Corrective Action

Module does not power

on.

Module is not fitted

correctly against

backplane.

Remove the module from the slot

and replace it in the slot to ensure

that the module is fitted correctly.

Place the module in a different slot

in the hub.

The hub is receiving

no electrical power.

Check that the hub is receiving

power.

Test for power at the wall outlet by

plugging in another device.

Select another outlet on a different

circuit if necessary.

Attached terminal does

not operate.

The terminal is

malfunctioning.

Follow the troubleshooting

procedures recommended by the

terminal manufacturer.

Cables are

unattached.

Make sure that the cable

connections at both ends are secure.

Cables are not the

correct type.

Make sure that the cable attached to

the terminal conforms to the

specification as described in

Appendix A.

The console or

auxiliary port is

configured

incorrectly.

Check the console port and auxiliary

port configurations.

You can make a TELNET connection

to the router to verify port

configurations.

Refer to the

Cisco Router Products

Configuration and Referenc

e

documentation for more

information. Verify that the port is

configured as 8-bit data, no parity,

1 stop bit, 9600 baud rate, with flow

control parameters set to Xon and

Xoff.

Advertising