Shutdown, Warning, Low voltage adjustment (smart guns only) – HP GRACO OR PRO TI1681A User Manual

Page 25: Table 4: low voltage adjustment

Advertising
background image

Operation

309293J

25

Shutdown

1.

Discharge the system voltage (page 20).

2.

Flush the spray gun. See page 26.

3.

Relieve the pressure (page 20).

4.

Hang the gun from its hook or place it in the acces-
sory holster, with the nozzle pointing down. Be sure
to keep the gun from grounding out.

Low Voltage Adjustment (Smart
Guns Only)

The ES HI/LO switch enables you to switch between full
voltage and a lower voltage output. The lower voltage is
factory set, but can be adjusted.

1.

Set the ES HI/LO switch to LO.

2.

Remove the LO VOLTAGE adjustment plug (53). Set
the desired voltage, using a small screwdriver to
slide switches 1 and 2 ON or OFF, according to
Table 4 . Also see F

IG

. 15..

Fig. 15. Low Voltage Adjustment Switches

WARNING

Pressurized Equipment Hazard

To reduce the risk of an injury, follow the
Pressure Relief Procedure on whenever
you are instructed to relieve the pressure.

ti1276a

ti1276a

ti1288a

Table 4: Low Voltage Adjustment

1

2

kV

ON

ON

50

Factory Setting

>

ON

OFF

40

OFF

ON

35

OFF

OFF

30

100

%

KV

μα

0

ti1529a

53

1

2

ON

OFF

Advertising