Chapter 8: Diagnostics/Maintenance

Diagnostics

Common Symptoms/Problems

Below is a list of common symptoms and problems you may encounter. Use this list as a guideline; if your
problem is not listed, use the diagnostic procedure explained in the beginning of this chapter.

Table 8-1 Common Symptoms/Problems

Common Symptom/Problem

Description/Solution

Unit will not turn on or LEDs on front lower
swing down panel of the chassis are unlit.

For AC units:
Check AC power source.
Check fuse or circuit breaker. To check fuse continuity, see
Inspect and Replace Fuse (for AC power only), later in this
chapter.

Ensure power supplies are fully seated.

For DC units:
Check that the supplies are fully seated in the DC chassis.

Check the customer premises over-current protection
device(s) are in the ON position.

For Tenor CMS860 and CMS240: Ensure all wires are
secured to the power entry plug and the plug is inserted to
the power receptacle and secured with the anchor screws.

Ensure the circuit breaker for the respective power entry
point is switched to the ON position.

Communication between Tenor CMS and
the PBX or PSTN cannot be established.

There are several reasons why communication may not be
successful. A few of the most common are listed below.

Verify correct cables are installed in the rear of the T1/E1/
DS1 ports. See Chapter 3: Installation.

Unit configuration may be wrong. Examine the configura-
tion parameters via CLI.

Network issues may cause a number of problems. Contact
the Central Office to perform test procedures.