P/N 480-0005-00-15

3-3

Chapter 3: Installation

Required Materials

NOTE:

Be certain to install all four screws provided or four screws of appropriate type as specified by the
rack manufacturer.

19” rack (not included with system)

#10 - 32 x 5/8 screws (qty: 4) (included with system)

#10 - 32 clip nuts (qty: 4) (included with system)

6 mm x 20 mm screws (qty 4) (included with system)

6 mm clip nuts (qty 4) (included with system)

screws as required by your rack manufacturer

Install the chassis in a rack as follows:

1. Choose a position for the chassis within the rack.

WARNING:

If the Tenor CMS chassis is the only equipment installed in the rack, ensure it is level with the
rack to avoid the rack from becoming unbalanced. Mount as low as possible to avoid a high
center of gravity.

NOTE:

For illustration purposes, the CMS (14 slot) is shown installed in the rack.

2. Align the chassis mounting brackets flush with the rack’s mounting holes (see Figure 3-1) and follow the

vendor specific instructions for rack installation. The screws provided require a Phillips #2 screwdriver.

3. Ensure the chassis is secured firmly to the rack at four points.