B. Constructing the Appliance Chase

A chase is a vertical box-like structure built to enclose the
gas appliance and/or its vent system. In cooler climates
the vent should be enclosed inside the chase.

NOTICE: Treatment of ceiling fi restops and wall shield
fi restops and construction of the chase may vary with the
type of building. These instructions are not substitutes
for the requirements of local building codes. Therefore,
you MUST check local building codes to determine the
requirements to these steps.

Chases should be constructed in the manner of all out-
side walls of the home to prevent cold air drafting prob-
lems. The chase should not break the outside building
envelope in any manner.

Walls, ceiling, base plate and cantilever fl oor of the chase
should be insulated. Vapor and air infi ltration barriers
should be installed in the chase as per regional codes for
the rest of the home. Additionally, in regions where cold
air infi ltration may be an issue, the inside surfaces may be
sheetrocked and taped for maximum air tightness.

Figure 5.2 Clearances to Combustibles

C. Clearances

NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly
on carpeting, vinyl, tile or any combustible material other
than wood.

WARNING! Risk of Fire! Maintain specifi ed air space
clearances to appliance and vent pipe:

• Insulation and other materials must be secured to prevent

accidental contact.

• The chase must be properly blocked to prevent blown

insulation or other combustibles from entering and
making contact with fi replace or chimney.

• Failure to maintain airspace may cause overheating and

a fi re.

To further prevent drafts, the wall shield and ceiling fi re-
stops should be caulked with high temperature caulk to
seal gaps. Gas line holes and other openings should be
caulked with high temp caulk or stuffed with unfaced in-
sulation. If the appliance is being installed on a cement
slab, a layer of plywood may be placed underneath to
prevent conducting cold up into the room.

* Adjust framing dimensions for interior sheathing (such as sheetrock)

* MINIMUM FRAMING DIMENSIONS

A

B

C

D

E

F

G

H

I

J

Rough

Opening

(Vent Pipe)

Rough

Opening

(Height)

Rough

Opening

(Depth)

Rough

Opening

(Width)

Clearance

to Ceiling

Combustible

Floor

Combustible

Flooring

Behind

Appliance

Sides of

Appliance

Front of

Appliance

Inches

10

40-1/2

22

49

32

0

0

1/2

1/2

36

mm

254

1029

559

1245

813

0

0

13

13

914

J

I

H

E

F

TOP OF

HOOD

TO

CEILING

G