E. Electrical Service and Repair

WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.

Figure 12.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram

Figure 12.3 Standing Pilot Ignition Wiring Diagram

WARNING! Risk of Shock! Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.

*Note: Appliance will not operate unless properly grounded.

IGNITION MODULE

3 VAC

TRANSFORMER

3 VAC

GRN

OR

G

INTERMITTENT

PILOT

IGNITOR

IGNITION

MODULE

(3V)

ON/OFF

WALL

SWITCH

LOW VOLTAGE

PLUG-IN

3V TRANSFORMER

NEUTRAL

HOT

GROUND

FLAME SPARKER/

SENSOR

REMOTE

CONTROL

SEE NOTE 1

ORG

WHT

VALVE

PIGGYBACK

ON/OFF SWITCH

WHITE WIRE

CAN BE

PLUGGED

INTO ANY

OF #1- #5

LOCATIONS

ON THE

NEUTRAL SIDE

BLACK WIRE CAN BE

PLUGGED INTO ANY OF

#1 - #5 LOCATIONS

ON THE HOT SIDE

BRN

BRN

VALVE

PLUG IN

GROUND TO
FIREPLACE
CHASSIS

I

S

BL

A

C

K

RED

BATTERY

PACK

Advertising
This manual is related to the following products: