One elbow two elbows, Top vent - horizontal termination, E. vent diagrams – Hearth and Home Technologies 8000TR-OAK User Manual

Page 25

Advertising
background image

Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev. P • 11/08

25

H

1

V

1

Figure 7.3

Figure 7.4

One Elbow

Two Elbows

Note: For corner installations: A 6 in.
(152 mm) section of straight pipe may
need to be attached to the appliance
before a 90º elbow, to allow the vent
pipe to clear the top standoffs.

INSTALLED

HORIZONTALLY

H

1

H

2

V

1

V

1

Minimum

H

1

Maximum

Elbow only

3 ft

924 mm

6 in.

152 mm

5-1/2 ft.

1.7 m

1 ft.

305 mm

8 ft.

2.4 m

2 ft.

610 mm

13 ft.

4.0 m

3 ft.

914 mm

18 ft.

5.5 m

V

1

+ H

1

= 40 ft. (12.2 m) Maximum

H

1

= 20 ft. (6.1 m) Maximum

V

1

Minimum

H

1

+ H

2

Maximum

Two 90º Elbows

back to back

Not approved

6 in.

152 mm

2-1/2 ft.

762 mm

1 ft.

305 mm

5 ft.

1.5 m

2 ft.

610 mm

10 ft.

3.1 m

3 ft.

914 mm

15 ft.

4.6 m

V

1

+ H

1

+ H

2

= 50 ft. (15.2 m) Maximum

H

1

+ H

2

= 17 ft. (5.2 m) Maximum

Top Vent - Horizontal Termination

Note: For corner installations: A 6 in.
(152 mm) section of straight pipe may
need to be attached to the appliance
before a 90º elbow, to allow the vent
pipe to clear the top standoffs.

E. Vent Diagrams