38

B. Rear Vent

NOTICE: Once appliance is set up for top or rear venting,
it CANNOT be changed at a later time.

Figure 9.6 Fold the tabs toward the center of the seal
cap (90º) and remove the insulation gasket.

Figure 9.7 Cut the metal retaining band and fold the
sides out.

Figure 9.8 Fold the center parts of the retaining band out
and use to remove the seal cap.

Figure 9.9 Discard the vent cap, remove and discard the
insulation basket.

Figure 9.10 Attach the fi rst vent section (it will snap into
place). Slide the insulation gasket onto the vent section,
up against the appliance and over the tabs.

NOTICE: Once the seal cap has been removed it CANNOT
be reattached.