Hawking Technology HNC720G User Manual

Page 49

Advertising
background image

General format of command URL

Every configuration can be set through URL with the POST method, by the Administrator only.

<general format>
URL[?[name=value][&name=value]……]
<method>
POST
<authorized user>
root

System configuration URL

URL: /setup/system.cgi

NAME

VALUE

DESCRIPTION

host

<text string shorter than 15 characters> system name
yes

turn off front LED

ledoff

no

turn off front LED

keep

keep date and time unchanged

auto

use NTP server to synchronize

method

manu

directly adjust date and time

date

<yyyy/mm/dd>

year, month and date separated by slash

time

<hh:mm:ss>

hour, minute and second separated by colon

ntp

<domain name or IP address>

NTP server

zone

-12 ~ 12

time zone, 8 means GMT +8:00

one hour

Synchronize with NTP hourly

one day

Synchronize with NTP daily

one week

Synchronize with NTP weekly

updateInterval

One month

Synchronize with NTP monthly

49