C. Clearances

NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly
on carpeting, vinyl, tile or any combustible material other
than wood.

WARNING! Risk of Fire! Maintain specifi ed air space
clearances to appliance and vent pipe:

• Insulation and other materials must be secured to prevent

accidental contact.

• The chase must be properly blocked to prevent blown

insulation or other combustibles from entering and
making contact with fi replace or chimney.

• Failure to maintain airspace may cause overheating and

a fi re.

C

B

D

A

Figure 5.2. Clearances to Combustibles

MINIMUM FRAMING DIMENSIONS*

A

B

C

D

E

F

G

H

I

J

Rough

Opening

(Vent Pipe)

Rough

Opening

(Height)

Rough

Opening

(Depth)

Rough

Opening

(Width)

Clearance

to Ceiling

Combustible

Floor

Combustible

Flooring

Behind

Appliance

Sides of

Appliance

Front of

Appliance

Inches

8-5/8

42 1/4

18-1/4

50

31

0

0

1

1

36

Millimeters

219

1073

464

1270

787

0

0

25

25

914

H

E

MEASURE FROM TOP

OF FIREPLACE OPENING

I

F

J

G

Note: Figure 5.2 shows the fi replace installed on the

fl oor. However, this fi replace can be elevated off the fl oor
provided that the fi replace is properly supported by framing
materials and the ceiling clearances are maintained.

* Adjust framing dimensions for interior sheathing (such as sheetrock)

Advertising