Electrical information – Heatiator Heatilator Rave4013i-c User Manual

Page 48

Advertising
background image

Heatilator • RAVE4013I-C • 2293-900 Rev. E • 2/13

48

A. Wiring Requirements

NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the Canadian Electric
Code CSA C22.1.

• Wire the appliance junction box to 110-120 VAC. This is

required for use of optional accessories (standing pilot
ignition) or proper operation of the appliance (IntelliFire
ignition).

• A 110-120 VAC circuit for this product must be protected

with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.

• Low voltage and 110-120 VAC voltage cannot be shared

within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire
110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.

B. IntelliFire Ignition System Wiring

• Wire the appliance junction box to 110-120 VAC for

proper operation of the appliance.

WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.

• Refer to Figure 12.2, IntelliFire Pilot Ignition (IPI) Wiring

Diagram.

• This appliance is equipped with an IntelliFire control valve

which operates on a 3 volt system.

Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.

12

12

Electrical Information

Optional Remote Control Receiver and Battery Pack

Location

Batteries are to be installed only when battery power is
required. Because of the limited accessibility to valve
cavity, the position of the battery pack, IPI control module,
and optional remote control receiver locations must be
installed as shown in Figure 12.1.

The battery pack, control module, and remote control
receiver can be accessed through the air space between
the fi rebox front and the lower-front fi nishing cover
panel. The decorative front and glass assembly must be
removed to access these components.

The battery pack is attached with velcro to the inside of
the lower cover panel. The IPI control module and the
remote control receiver are placed on the fi rebox bottom.

• Plug the 3-volt AC transformer into the appliance junction

box to supply power to the unit OR install two D cell
batteries (not included) into the battery pack before
use.

NOTICE: Batteries should not be placed in the battery
pack while using the transformer. Remove batteries
before using the transformer, and unplug the transformer
before installing the batteries. Battery polarity must be
correct or module damage will occur.

C. Optional Accessories Requirements

• This appliance may be used with a wall switch, wall

mounted thermostat and/or a remote control.

NOTE: Install optional remote receiver adjacent to battery
pack. See Figure 11.5.

GAS VALVE

CONTROL
MODULE

DC ADAPTER

BATTERY

PACK

CONTROL MODULE GROUND

Figure 12.1 Valve Cavity

Advertising