Finishing – Heatiator Heatilator Rave4013i-c User Manual

Page 50

Advertising
background image

Heatilator • RAVE4013I-C • 2293-900 Rev. E • 2/13

50

13

13

Finishing

A. Framing and Finishing Instructions

WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)

Finishing Instructions

It is important to follow the framing and fi nishing instruc-

tions to ensure proper placement of fi replace into the sur-
rounding framing/fi nishing materials.

Wall sheathing materials 1/2 in. thick are specifi ed in

this installation manual to properly align with the factory-
installed non combustible material.

WARNING! Risk of Fire! DO NOT remove the factory-
installed non-combustible board or cover it with combus-
tible material, such as:

• Drywall (gypsum board)

• Plywood

• Materials that do not meet the ASTM E 136 Non-com-

bustibility standard (below).

Removal of factory-installed, non-combustible board and/

or use of materials not meeting the ASTM E 136 standard
may cause fi re.

Non-Combustible Materials Specifi cation

Material which will not ignite and burn. Such materials are

those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136,

Standard Test Method for Behavior of Materials in
a Vertical Tube Furnace at 750 ºC
shall be considered
non-combustible materials.

Setting the Fireplace into the Framing

Unlike many traditional, single-sided Heatilator fi replaces,

this fi replace is recessed into surround framing. The left
and right nailing tabs were designed for the RAVE4013I-C
model as a means to ensure the fi replace is recessed to
the correct location within the framing materials.

1. Bend two nailing tabs away from fi replace 180 degrees

on both left and right nailing tabs. See Figure 13.1.

2. Screw each nailing tab to the adjoining framing ma-

terial. Ensure that the 1 inch air space clearance is
maintained on the sides of the fi replace.

Figure 13.1 Nailing Tabs Installation Position

NAILING
TABS

FACTORY-INSTALLED

NON-COMBUSTIBLE BOARD

Advertising