Heatilator • RAVE4013I-C • 2293-900 Rev. E • 2/13

Clearances to Combustibles:

Refer to Section 5 for clearances to the appliance, man-
tel, mantel legs and wall projection.

Refer to Section 8 for pipe clearances to combustibles.

Termination Cap

For installation of termination cap see minimum vent
heights for various pitched roofs. See Section 6 of appli-
ance owner’s manual.

Flue Damper

Fully lock the solid fuel fi replace’s fl ue damper in the open
position, OR completely remove it.

Venting Components

The LINK-DV30B is approved for use with the coaxial/co-
linear venting application. The LINK-DV30B kit includes:

• Two 30 feet sections of fl exible vent pipe (3 inches Ø).

One section is used to draw combustion air and the other
section is used to expel exhaust gases.

• One vertical termination cap.

WARNING! Risk of Fire! Coaxial to colinear venting
confi guration may only be used in existing non-combus-
tible chimney. Installation in any other venting application
could cause fi re.

Prior to installing the gas appliance:

• Have the chimney and adjacent structure inspected

and cleaned by qualifi ed professionals. Hearth & Home
Technologies recommends that NFI or CSIA certifi ed pro-
fessionals, or technicians under the direction of certifi ed
professionals, conduct a minimum of a NFPA 211 Level
2 inspection of the chimney.

• Replace component parts of the chimney and fi replace

as specifi ed by the professionals.

• Ensure all joints are properly engaged and the chimney

is properly secured.

EXHAUST VENT PIPE

INLET AIR VENT PIPE

Figure 7.14 Coaxial/Colinear Appliance Adapter (DV-46DVA-GCL)

Coaxial to Colinear Venting

The coaxial to colinear adapter (DV-46DVA-GCL) is ap-
proved for installations into solid fuel masonry or factory
built fi replaces that have been installed in accordance
with the National, Provincial, State and local building
codes. The DV-46DVA-GCL must be recessed into exist-
ing masonry fi replace. See Table 1 and Figure 7.15.

OUTSIDE FACE OF

FIREPLACE

TOP OF FIREPLACE

OPENING

SHADED AREA DEFINED AS

“INSIDE EXISTING MASONRY FIREPLACE”

3 IN. MIN.

5 IN. MIN.

EXHAUST VENT PIPE

Figure 7.15 Existing Fireplace DV-46DVA-GCL Clearance
Requirements

Table 1

CLEARANCE TO COMBUSTIBLES REQUIREMENTS

DV-46DVA-GCL 3

IN.

Exhaust Vent Pipe

5 IN.

CAUTION! DO NOT use any fl ue restrictor when vent-
ing with the DV-46DVA-GCL adapter and LINK-DV30B
kit.
This may result in poor fl ame appearance, sooting,
pilot malfunction, or overheating.