E. junction box installation, D. electrical service and repair – Heatiator Heatilator Rave4013i-c User Manual

Page 49

Advertising
background image

49

Heatilator • RAVE4013I-C • 2293-900 Rev. E • 2/13

Figure 12.2 IntelliFire Pilot Ignition (IPI) Wiring Diagram with Wall Switch or Thermostat

E. Junction Box Installation

1. Bend junction box heat shield to the right along the

perforated hand bends.

2. Remove the one screw located in front of the junction

box.

3. Remove the plastic electrical knockout slug in the top

of the junction box.

4. Install wire strain (not included) and route wire through

wire strain fi tting.

5. Make the connections inside the junction box to the

120V wire. Connect the green wire to the ground nut,
the black wire to the black wire and the white wire to
the white wire.

6. Reinstall the junction box.

7. Reposition the junction box heat shield such that it is

positioned over the junction box.

TRANSFORMER

3 VAC

PLUG IN

BLACK

RED

BATTERY PACK

WIRE ASSEMBLY

WIRES
(TO BROWN)

ORANGE

GREEN

VALVE

WHITE

ORANGE

IGNITION MODULE 3 VAC

INTERMITTENT PILOT IGNITOR

HOT

NEUTRAL

I

S

GROUND TO

FIREPLACE

CHASSIS

NOTE: 1. Ignition module, valve, pilot, and
wall switch operate on 3 volts. 120 VAC is
required at junction box unless equipped
with battery back-up.

D. Electrical Service and Repair

WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.

WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.

Note: There is an alternative access to the junction box.
This can be accessed by removing the valve assembly. See
Section 11.

Advertising