Heatiator Heatilator Rave4013i-c User Manual

Page 26

Advertising
background image

Heatilator • RAVE4013I-C • 2293-900 Rev. E • 2/13

26

INSTALLED

HORIZONTALLY

H

1

H

2

V

1

Figure 7.5

1. Top Vent - Horizontal Termination - (continued)

Top Vent - Horizontal Termination

Venting with 2 elbows

Note: Use SLP Series
components only.

V Minimum

H

1

+ H

2

MAXIMUM

RAVE4013I-C

90° Elbow

1 ft.

305 mm

1 ft.

305 mm

2 ft.

610 mm

2 ft.

610 mm

4 ft.

1.2 m

3 ft.

914 mm

6 ft.

1.8 m

4 ft.

1.2 m

15 ft.

4.6 m

H

1

+ H

2

MAX. =15 ft. (4.6 m)

V + H

1

+ H

2

MAX. = 40 ft. (12.2 m)

Note: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 7.3).

CAUTION: The SLP-HRC-SS and SLP-HRC-ZC-SS
termination caps are not approved for use with pro-
pane (LP) fuel. May lead to elevated glass temper-
ature that may cause tempered glass breakage.