Heatilator • RAVE4013I-C • 2293-900 Rev. E • 2/13

30

Figure 7.11

H

1

V

1

V

2

Top Vent - Vertical Termination

Venting with 2 elbows

Note: Use SLP Series
components only.

RAVE4013I-C

V

1

Minimum

H Maximum

V

2

V

1

+ V

2

Minimum

90° Elbow

2 ft.

610 mm

*

*

1 ft,

152 mm

3 ft.

914 mm

*

*

2 ft.

457 mm

5 ft.

1.5 m

*

*

3 ft.

914 mm

7 ft.

2.1 m

*

*

4 ft.

1.1 m

15 ft.

4.6 m

*

*

H MAX. =15 ft. (4.6 m)

V

1

+ V

2

+ H MAX. = 40 ft. (12.2 m)

* No specifi c restrictions on this value EXCEPT V

1

+ V

2

+ H cannot exceed 40 ft. (12.2 m)

Note: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 7.3).