D. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).

Figure 5.3 Clearances To Combustible Mantels Or Other

Combustibles Above Appliance

Figure 5.4 Clearances To Non-Combustible Mantels Or Other

Non-Combustibles Above Appliance

Combustible Mantels

Non-combustible Mantels

Figure 5.5 Combustible Mantel Leg or Wall Projections

(Acceptable on both sides of opening)

Figure 5.6 Non-Combustible Mantel Leg or Wall Projections

(Acceptable on both sides of opening)

Combustible Mantel Legs Or Wall Projections
Extending Past The Face Of The Fireplace

Non-combustible Mantel Legs Or Wall Projections
Extending Past The Face Of The Fireplace

3 FT. MAXIMUM

6 IN.

MINIMUM

2 IN.

MINIMUM

FIREPLACE

OPENING

3 IN.

MINIMUM

UNLIMITED

7 IN.

FIREPLACE

OPENING

14 IN.

MIN.

12 IN.

MAX.

1/2 IN.
Thick Wall
Sheathing

MEASUREMENT
FROM TOP OF
FIREPLACE
OPENING

Note: For non-combustible fi replace fi nish material (marble,
stone, etc) specifi cations refer to Section 13.C.

14 IN.

MIN.

12 IN.

MAX.

1/2 IN.
Thick Wall
Sheathing

MEASUREMENT
FROM TOP OF
FIREPLACE
OPENING

4 IN.

MAX.

1 IN.MIN.

Figure 5.7 Front Side Finishing Detail

1 IN.

FRAMING

1/2 IN. FACTORY-SUPPLIED
NON-COMBUSTIBLE BOARD

NAILING TAB

Advertising