6 loran td correction, Cancelling chart position correction – Furuno GP-3300 User Manual

Page 104

Advertising
background image

11-7

2. Select YES from the POS CORR field.

3. Select

L/L from the MODE field.

4. Enter latitude and longitude correction values.

5. Press the [ENT] key.

Cancelling chart position correction

1. Press [MENU] and [6].

2. Select NO from the POS CORR field.

3. Press the [ENT] key.

11.6 Loran TD Correction

When the Loran A or Loran C TD display shows constant error you
can correct it as follows:

1. Press the [MENU] key.

8 INITIAL SETTINGS

AUTOPILOT DISPLAY = ON

OFF

TD INDICATION

= LA

LC

OFF

STATION PAIR

= 00-01

TO CORRECTION 1

= 000.0

µ

S

TO CORRECTION 2

= 000.0

µ

S

SELF TEST

: OK

PROGRAM NO.

: 14517020xx

Figure 11-10 INITIAL SETTINGS menu, lower half

2. Press the [8] key to display the INITIAL SETTINGS menu.

3. Select TD CORRECTION 1.

4. Enter TD correction value in microseconds. If the value is -0.1

microseconds, for example, press [0], [0], [0], and [1].

5. Select TD CORRECTION 2 and enter TD correction value in

microseconds.

6. Press the [ENT] key.