7 setting plot interval 1 by time, Setting plot interval 2 to “time – Furuno GP-3300 User Manual

Page 38

Advertising
background image

2-7

Setting plot interval 1 by time

The default plot method for plot interval 1 is time. To set plot interval
1 by time do the following:

1. Press the [MENU] key.

2. Press the [8] key to select INITIAL SETTINGS.

3. Select the PLOT INTERVAL 1 field

.

8 INITIAL SETTINGS

INTERNAL NAV

= ON

OFF

EXTERNAL NAV

= GPS LC LA DC DR OFF

I/O DATA FORMAT

= CIF NMEA183 NMEA180/182

SMOOTHING

= 00 (0-15)

PLOT INTERVAL 1

= TIME (00M10S) DIST (0.10NM)

PLOT INTERVAL 2

= TIME (00M10S) DIST (0.10NM)

WAYPOINT MARK

= ON

OFF

Figure 2-11 INITIAL SETTINGS menu

4. Enter a plot interval. To enter 30 seconds, for example, press [0],

[0], [3] and [0].

5. Press the [ENT] key.

Setting plot interval 2 to “time”

The default plot method for PLOT INTERVAL 2 is distance. How-
ever, it may be set for time as follows:

1. Press the [MENU] key.

2. Press the [8] key to select INITIAL SETTINGS.

3. Select the PLOT INTERVAL 2 field.

4. Select TIME.

5. Enter a plot interval. To enter 15 minutes, for example, press [1],

[5], [0], [0].

6. Press the [ENT] key.