Frequency

Maximum Input at Upper Frequency

20 Hz - 50 Hz

300 V rms

50 Hz - 100 Hz

300 V rms

100 Hz - 10 kHz

200 V rms

10 kHz - 20 kHz

100 V rms

20 kHz - 50 kHz

40 V rms

50 kHz - 100 kHz

20 V rms

Input Impedance

1 M

in parallel with 100 pF maximum Maximum

Maximum Crest Factor

3.0

2.0 for rated accuracy

Crest Factor Error

Non-sinusoidal input signals with crest factors between 2 and 3 and pulse widths 100 µs
and longer add 0.2% to the accuracy specifications.

Common Mode Rejection

80 dB minimum at 50 or 60 Hz ± 0.1%, 1 k

imbalance, slow rate

Maximum AC Input

300V rms or 424V peak on channels 0, 1, and 11
150V rms or 212V peak on channels 2 to 10 and 12 to 20
Voltage ratings between channels must not be exceeded

2 x 10

6

Volt-Hertz product on any range, normal mode input

1 x 10

6

Volt-Hertz product on any range, common mode input

DC Component Error

SCAN and first MONitor measurements will be incorrect if the dc signal component
exceeds 60 counts in slow rate or 10 counts in fast rate. To measure ac with a dc
component present, MONitor the input and wait 5 seconds before recording the