10. oxygEn dEPLETIon SEnSor

The fire is fitted with an oxygen sensitive pilot system that

will act to cut off the gas supply to the fire should the

oxygen in the room fall below its normal level. If the fire is

turned off by this device, it usually indicates that there is a

problem with the flue system, and this should be inspected

by a qualified engineer. Do not attempt to use the fire until

an engineer says it is safe to do so.

This device is not a substitute for an independently

mounted carbon monoxide detector.

11. FLAME FAILURE DEvICE

This is a safety feature incorporated in all GAZCO fires

which automatically switches off the gas supply if the pilot

light goes out and fails to heat the thermocouple.

12. RUNNING IN

The surface coating on the coals used in your GAZCO fire

will burn off during the first few hours of use, producing a

harmless and temporary odour. This will disappear after a

short period of use. If the odour persists, ask your installer

for advice.

13. SERvICING

The fire must be serviced every 12 months by a qualified

Gas Engineer. In all correspondence, always quote the fire

type and serial number, which may be found on the data

badge located on chain beneath the control valve.

14. vENTILATION

Any purpose provided ventilation should be checked

periodically to ensure that it is free from obstruction.

15. INSTALLATION DETAILS

To assist in any future correspondence, your installer should

have completed the commissioning sheet at the front of this

manual. In all correspondence always quote the Model

Number and Serial Number.