INSTALLATION INSTRUCTIONS

INSTALLATION

10

6.14 Turn the appliance off, disconnect the “U” gauge and

replace the sealing screw. Relight the appliance and check

the sealing screw for leaks.

7. FITTING ThE DECORATIvE INNER

PANEL

7.1 By rotating the panel, insert into fire box, Diagram 11.

11

AR1880

7.2 Check that the panel is sitting behind the rear ledge, but in

front of the spacer bracket so that it locates in the slot,

Diagram 12.

12

AR1930

7.3 Secure the panel using the two upper brackets and the

pozidrive screws, Diagram 13. Use only the rearmost hole

in the retaining bracket on each side.

18

8

AR1157

6.7 Coil up the surplus cable and locate in the back of the

firebox.

NEvER ShORTEN ThE CABLES, ThEy wILL BE REQUIRED
whEN SERvICING ThE APPLIANCE.

6.8 Replace the lower cover plate.

Note:

The cable adjuster may need to be tucked upward in

order to fit the lower cover plate.

B) SCrEW FIxIng METHod

6.9 Alternatively, this appliance can be secured back to the

fireplace opening using the screws and rawl plugs provided.

Place the firebox centrally in the opening and mark the

positions of the 4 fixing holes. Drill the holes and insert the

4 rawl plugs. See diagram 9

9

AR1375

6.10 Offer the firebox into the opening and ensure that the gas

supply pipe passes through the rubber seal.

6.11 Refit the burner assembly and secure the 5 pozidrive

screws. Connect the gas supply to the inlet connection on

the burner unit and tighten. It may be necessary to support

the inlet connection with another spanner whilst tightening

this joint. See diagram 10.

6.12 Turn on the gas supply to the appliance and check for

leaks. Light the fire and check all joints on the appliance for

leaks.

6.13 Remove the sealing screw from the inlet connection and

connect a suitable “U” gauge manometer. Light the fire and

turn to the maximum position, refer to the data badge and

ensure that the running pressure is correct. If the pressure

varies significantly from that on the data badge, this may

indicate a supply problem and will require immediate

attention.

Advertising