5.3 Decide on the retention method. If cable fixings are to be

used remove the lower cover plate by unscrewing the three

screws., Diagram 3.

3

AR1376

Then remove the two knockout holes on the rear of the box

using a sharp hammer blow, Diagram 4.

4

AR1369

5.4 Remove the backing from the self-adhesive silicone sealing

strip and apply to the rear flange of the firebox ensuring that

it is positioned as close to the outer edge as is practically

possible, Diagram 5.

5

AR1369

5.5 Gas pipe entry must come through the right-hand side of

the box. The rubber seal must be cut using a sharp knife to

allow the isolating elbow to pass through it. Ensure the

rubber is not damaged when doing this.

A means of isolation is provided with the fire. This must be fitted

to the supply pipe prior to installing the firebox.

INSTALLATION INSTRUCTIONS

INSTALLATION

6. InSTaLLaTIon oF THE FIrE

6.1 Ensure that the fireplace opening is in compliance with

Section 2 Site Requirements then proceed as follows:

A) CABLE RETENTION METhOD
6.2 Mark the position of the 4 fixing holes on the rear of the

fireplace opening and drill the holes using a 6.5mm

masonry drill bit. Insert the 4 fibre rawl plugs and screw the

eyebolts in as far as possible leaving the eye horizontal,

Diagram 6.

6

AR1205

6.3 Pass the 2 cables through the holes in the bracket on the

back of the firebox and pull taut so that the stop ends sit

tightly against the top of the bracket, Diagram 7

7

AR1155

6.4 Pass the cables vertically through the 2 sets of eyebolts and

thread the ends through the holes in the lower back of the

firebox. Pass the gas supply pipe through the hole in the

rubber seal (refer to section 5.5) and push the fire into

place.

6.5 Thread the cables through the tensioner bolts and push the

threaded portions through the holes in the firebox so that

the lock nut sits against the back wall (ensure that the nut is

screwed fully up to the head of the tensioner to allow

maximum adjustment).

6.6 Slide the locking nipples onto the cables, pull the cables taut

and tighten the locking screw. Adjust the lock nuts using a

10mm spanner until the silicone sealing strip forms a tight

seal between the fireplace opening and the firebox flange,

Diagram 8

Advertising