G0605X/G0606X Extreme Series 12" Table Saw

Operation

SECTION 2: CIRCUIT REQUIREMENTS

Full Load Amperage Draw Draw

G0605X @ 220V .................................. 23 Amps
G0606X @ 220V .................................. 19 Amps
G0606X @ 440V* ................................. 10 Amps

Circuit Requirements

You MUST connect your machine to a grounded
circuit that is rated for the amperage given below.
Never replace a circuit breaker on an existing cir-
cuit with one of higher amperage without consult-
ing a qualified electrician to ensure compliance
with wiring codes.

If you are unsure about the

wiring codes in your area or you plan to con-

nect your machine to a shared circuit, consult

a qualified electrician.

G0605X @ 220V .................................. 30 Amps
G0605X @ 220V .................................. 30 Amps
G0606X @ 440V .................................. 15 Amps

Serious personal injury could occur if you

connect the machine to power before com-

pleting the setup process. DO NOT connect

the machine to the power until instructed

later in this manual.

Electrocution or fire could

result if machine is not

grounded and installed in

compliance with electrical

codes. Compliance MUST

be verified by a qualified

electrician!

Figure 2. Recommended connection types.

�������

��

�������

�������

��

������������

L6-30

Plug & Outlet

for 220V, Single-

Phase

Hardwired Locking

Disconnect Switch

for 440V, 3-Phase

Power Connection Device

The power connection device depends on the
type of installed or planned service. We recom-
mend using one of the devices shown in

Figure

2, depending on the voltage being used.

G0605X @220V Single-Phase .................. L6-30
G0606X @220V 3-Phase .........................L15-30
G0606X @440V 3-Phs ..........Hardwired Locking
Disconnect Switch

For 440V connections, an electrician MUST
hardwire the machine (using a metal conduit
setup) directly to a locking disconnect switch,
which is directly connected to the power source.

L15-30

Plug & Outlet

for 220V, 3-Phase