3.7.3 SOUND ATTENUATED UNITS

1. Carefully inspect the governor anti-lash

spring (Figure 3.3). Be sure it is not broken

or disengaged.

2. Loosen the governor clamp nut. Then, push the

spring end of the governor lever all the way up

(wide open throttle).

3. Hold the governor lever at wide open throttle and

insert the tip of a screwdriver into the slotted end

of the governor shaft.

• Hold the governor lever at wide open throttle and

rotate the governor shaft fully counterclockwise.

• Hold the governor shaft fully counterclockwise

and tighten the governor clamp nut to 70 inch-

pounds (8 N-m) torque.

Figure 3.3 – Sound Attenuated

Engine Governor Adjustment

3.8 VOLTAGE

REGULATOR

ADJUSTMENT

With the frequency between 61-62 Hertz, slowly turn

the slotted potentiometer (Figure 3.4) until line volt-

age reads 244-252 volts.

NOTE:

You must remove the roof to adjust the voltage
regulator on nonsound attenuated units.

Figure 3.4 – Voltage Adjustment Potentiometer

NOTE:

The voltage regulator is housed in the generator's
control panel. The regulator maintains
a voltage in direct proportion to frequency at a 2-
to-1 ratio. For example, at 62 Hertz, line-to-neu-
tral voltage will be 124 volts.

3.9 OVERSPEED

ADJUSTMENT

3.9.1 6 KW, 8 KW AND 10 KW UNITS (NON-SA)

See item 3 of Section 1.15 on Page 15 for overspeed

adjustment information for these units.

3.9.2 SOUND ATTENUATED UNITS

Use the following overspeed adjustment procedure:
1. For initial setting, turn the potentiometer fully

clockwise.*

2. Start the engine and increase the governed

speed setting to 72 Hertz (62 Hertz for 50 Hertz

rated units).

*NOTE:

If immediate shutdown occurs when the engine
starts, reverse the potentiometer setting done
in item 1.

3. Turn the adjustment potentiometer slowly until

the engine shuts down.

4. Readjust the governor to the rated speed.

Section 3 — Post-installation Start-up Adjustments