DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROL

Page 24

January 2000

TRACTION

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-09

Both the forward and reverse
directional switches are closed at the
same time.

This status code will be displayed when P4 and P5
are greater than 60% of battery volts at the same
time.

MEMORY RECALL

NO

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Traction

Controller

SYMPTOM
Control will not operate.

POSSIBLE CAUSE
Forward or reverse directional switch welded
closed or mis-adjusted to be held closed.

= Replace or adjust directional switches to

insure that they open when directional switch
is returned to neutral.


Short circuit between battery positive and P4
and/or P5.

= Disconnect wires from P4 and P5 and check

wire for short circuit to positive side of
directional switch.


Defective Control

= Disconnect wires and measure voltage at P4

and P5. Voltage should be less than 60% of
battery volts.

KEY

SWITCH

P1

P2

P3

P17

P5

REVERSE SW

.

F

O

RWARD SW.

P4

SEAT

SW

IT

CH

P6

L

ST

ART

SW

.

TRACTION

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-10

Steer angle potentiometer voltage is
too high.

This status code will be displayed when P12 is greater
than 3.9 volts.

MEMORY RECALL

NO

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Traction

Controller

SYMPTOM
Control will not operate.

POSSIBLE CAUSE
Steer angle potentiometer input mis-adjusted or
defective. Loose or missing connections at P8,
P12 or P9.

= Input voltage at P12 should be less than 3.9

volts at all times. Insure that the adjustment
of the steer potentiometer is in accordance
with Section 9 of this instruction.


Defective control.

= Replace control unit.

P9

P12

P8

STEER ANGLE

POT