GE SX TRANSISTOR CONTROL IC3645SR4U404N2 User Manual

Page 59

Advertising
background image

ADJUSTABLE FEATURES

SX TRANSISTOR CONTROLS

Page

59

January 2000

FUNCTION 13

SPEED LIMIT 3

( Push 13 )

The SL3 set speed limit is activated by the Truck

Management Module 90, 91 and 92. See Section 5 for

Truck Management Module details.


FUNCTION 14

INTERNAL RESISTANCE
COMPENSATION

( Push 14 )

This function is used when the Battery Discharge Indicator

is present. Adjustment of this function will improve the

accuracy of the BDI. In order to determine this setting the

voltage drop of the battery under load must first be

calculated by the following method:

1. Load the traction motor to 100 amps at 100% on-time of

the control and record the open circuit voltage (V

O

) at

the control panel positive and negative power terminal.

2. Load the traction motor to 200 amps at 100% on time of

the control and record the voltage (V

L

) at the control

panel positive and negative power terminal.

3. Calculate voltage drop (V

Drop

) as follows:

V

Drop

= V

O

- V

L

4. Use the table below to determine the appropriate setting

using the calculated V

Drop

as a reference.

INTERNAL RESISTANCE COMPENSATION

TABLE

Setting V

Drop

Setting V

Drop

2 11.44 17 01.34
3 07.60 18 01.27
4 05.72 19 01.20
5 04.57 20 01.14
6 03.81 21 01.09
7 03.27 22 01.04
8 02.86 23 00.99
9 02.54 24 00.95

10 02.28 25 00.91
11 02.08 26 00.88
12 01.90 27 00.85
13 01.76 28 00.82
14 01.63 29 00.79
15 01.52 30 00.76
16 01.43 31 00.74


FUNCTION 15

BATTERY VOLTS

(Push

l5)

This function allows for the adjustment of voltage range for

controls equipped with the Battery Discharge Indication

function. In order for the BDI to operate properly, the

setting as shown in the table must be entered:

Battery volts

Set units

24 volts

Between 0 and 31

36 volts

Between 32 and 44

48 volts

Between 45 and 69

72 volts

Between 70 and 80

80 volts

Between 81 and 183

36/48 volts

Between 184 and 250

No BDI

Between 251 and 255

.FUNCTION 16 STALL TRIP POINT WITH % ON-TIME

( Push CONT 1)


This function allows for the adjustment of control percent

on time for the stall motor trip point

Control % On time = 163 -(Set Point Val)*.892

If 163 or greater, then “0.0” % on time

If 51 or less, then “100.”% on-time

FUNCTION 17

CARD TYPE SELECTION

( Push CONT 2 )

This function allows for the selection of the card type used

for your vehicle's application. The table below shows the

setting to select card application type, depending on which

control card is used. Note that the right (slave) control for

a dual motor proportioning system will be set differently

than the left (master) control.

Note: Non-Auto Plug/Regen Logic cards must be used for

settings below:


FUNCTIONS STANDARD REGEN
Std C/L

5 to 9

45 to 49

Std C/L (Right)

69 to 73

109 to 113

Note: Auto Plug/Regen Logic cards must be used for

settings below:


FUNCTIONS STANDARD

REGEN

Std C/L Auto Plug

15 to 19

55 to 59

Std C/L Auto Plug (Right)

79 to 83

119 to 123

Settings for these functions should be made within the

ranges indicated above.


Warning: These settings must be changed by authorized
personnel only, following instructions supplied by the

The following functions have function numbers larger

than the numbers on the Handset keyboard. To access

these functions, push the CONT key and the number

shown in the following instructions at the same time.

Advertising