ADJUSTABLE FEATURES

SX TRANSISTOR CONTROLS

Page

57

January 2000

ESC

ESC

ESC

ESC

LX

HANDSET

g

EVC

CONT

CONT

CONT

CONT

STORE

STORE

STORE

STORE

1

5

+

+

9

13

2

6

10

14

3

7

11

15

4

8

12

Section 6.4 Setup Functions for Traction Controller

FUNCTION 1

MOTOR VOLTS TO ENABLE AUTO REGEN

(Push

1)


This function allows for the adjustment of motor volts to

enable AutoRegen.

For a setting value of less than 25 (corresponding to a soft

release of auto regen and normal regen), the motor voltage

to enable regen is calculated by multiplying the value of the

setting by 0.375. For example, a setting of 16 will be

multiplied by 0.375 to enable regen at 6 motor volts.

Vm = VAL(setting) X .375

For a setting value of greater than 25, the motor voltage to

enable auto regen is calculated by subtracting 25 from the

setting value and multiplying that number by 0.375. For

example, a setting of 33, the motor volts necessary to

enable auto regen is (33 - 25) x 0.375, or 3 volts.

FUNCTION 2

CREEP SPEED

(Push

2)


This function allows for the adjustment of the creep speed

of the vehicle. Creep speed can be adjusted when an

accelerator input voltage between 3.9 and 3.3 volts or an

accelerator ohm input between 6.0K and 4.0K ohms is

provided.

Range

2% to 15% on-time

Set

0

to

255

Resolution

0.05% per set unit

Example

Setting of 20 = 3% on-time


Important Note: This function is used to optimize motor
and control performance, and this setting will be
determined by GE and OEM engineers at the time of
vehicle development. This setting must not be changed by
field personnel without the permission of the OEM.


FUNCTION 3

ARMATURE CONTROLLED
ACCELERATION

(Push

3)

This function allows for the adjustment of the rate of time it

takes for the control to accelerate to 100% applied battery

voltage to the motor on hard acceleration.

Range

0.025 to 6.3 seconds

Set

0 to 255

Resolution

0.025 seconds per set unit

Example:

Setting of 20 = 0.5 seconds

FUNCTION 4

ARMATURE CURRENT LIMIT

(Push

4)


This function allows for the adjustment of the armature

current limit of the control. The rating of the control will

determine the range of adjustment for this function. Please

refer to the specification sheets and current limit curves for

the control used in your vehicle.

Range

See control C/L curves

Set

0 to 255

Example:

0 = min. current, 255 = max.

current


FUNCTION 5

PLUGGING DISTANCE (CURRENT)

(Push

5)

This function allows for the adjustment of the plugging

distance of the vehicle. The larger the current setting, the

shorter the stopping distance.


Min Max Set

Resolution

Per Unit Value

Example
If Set at 20

55

455

0 to 255

1.57 amps

86.4 amps

Warning: Plug settings must be made in accordance with

control operating instructions. Too high of a setting could

cause damage to the control system or traction motor.