DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROL

Page 44

January 2000

TRACTION

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-95

Pump motor brush wear indicator has
detected worn brush.

This status code will be displayed when the voltage at
the respective terminal of the TMM or Pump Logic
Card is at battery volts.

MEMORY RECALL

YES

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Pump

Motor

Brush Wear

Indicator



SYMPTOM
Status code flashes “on and off”.

POSSIBLE CAUSE
User defined status code is displayed by motor
brush sensor closure to battery positive.

Plug P8 (pump) is shorted to positive.

Defective input switch (shorted).

Defective TMM card.

Defective pump card.

SC95

POS

P8

USER SW

WHEN SR Series PUMP

CONTROL IS USED

TRACTION

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-95

Pump motor brush wear indicator has
detected worn brush.

This status code will be displayed when the voltage at
the respective terminal of the TMM or Pump Logic
Card is at battery volts.

MEMORY RECALL

YES

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Pump

Motor

Brush Wear

Indicator



SYMPTOM
Status code flashes “on and off”.

POSSIBLE CAUSE
User defined status code is displayed by motor
brush sensor closure to battery positive.

Plug P9 (pump) is shorted to positive.

Defective input switch (shorted).

Defective TMM card.

Defective pump card.

SC95A

POS

P9

USER SW

WHEN SR Series PUMP

CONTROL IS USED

Advertising