GE SX TRANSISTOR CONTROL IC3645SR4U404N2 User Manual

Page 65

Advertising
background image

ADJUSTABLE FEATURES
TRANSISTOR PUMP CONTROLS

Page 65

August 1999

of 0.375 volts each whereas, a setting of 4 will be added in

15 steps of 0.375 volts each.

SPEED / TORQUE

COMPENSATION TABLE

SETTING

VOLTAGE

DROP

SETTING

VOLTAGE

DROP

2 11.44 17 1.34
3 7.60 18 1.27
4 5.72 19 1.20
5 4.57 20 1.14
6 3.81 21 1.09
7 3.27 22 1.04
8 2.86 23 0.99
9 2.54 24 0.95

10 2.28 25 0.91
11 2.08 26 0.88
12 1.90 27 0.85
13 1.76 28 0.82
14 1.63 29 0.79
15 1.52 30 0.76
16 1.43 31 0.74


FUNCTION 17: CARD TYPE SELECTION

(Push CONT 2)

This function should be set in accordance with the control

type in use in the vehicle:

Function

Without Pump

Ctr/PMT

High C/L

BDI Lockout

63 to 71

BDI Lockout means that the BDI signal from the traction

control must be present in order for the pump control to

operate. This control will stop operation when the battery

state of charge reaches 10%.

Settings for these functions should be made in between the

values shown.

Warning: These setting must be changed by authorized
personnel only, following instructions supplied by the
manufacturer. Card type selection must be made within
the capabilities of the TRANSISTOR control panel used
and the supporting electro-mechanical devices. Failure to
comply with proper application standards could result in
mis-operation or damage to the control and/or motors.

FUNCTION 28:

FAULT COUNT POINTER

(Push CONT 13)

This register contains the location of the last stored status

code recorded of the 16 stored status codes. These stored

status codes have caused a PMT controller shutdown

and/or disruption of normal vehicle operation.

To determine which stored status code was the last one

recorded, read the number stored in Function 28. Using the
Memory Map (See Section 8.1) for your logic card, match
the “stored status code pointer number” (the number
shown in (bold italics) in the HS (Handset) number column)

on the memory map, with the number obtained from

Function 28. This will be the last stored status code

recorded.


Note: When scrolling the stored status code register, the
register always starts at status code 1 and scrolls to
status code 16. Instructions for scrolling the register are
in Section 6.3.2 of this instruction booklet.

FUNCTION 48:

MODE 1 - CONTROLLED ACCELERATION

(Push CONT 1)

This function allows for the adjustment of the rate of time it

takes for the control to accelerate to 96% applied battery

voltage to the motor on hard acceleration.

Range

0.1 to 22.0 seconds

Setting

0 to 255

Resolution

0.084 seconds per set unit

Example: Setting of 20 = 1.8 seconds C/A

FUNCTION 49:

MODE 1 - SPEED LIMIT 2 (SL2)

(Push CONT 2)


This function allows for the adjustment of the speed limit

(maximum battery volts to the motor) when the SL2 limit

switch input signal is received by the control card. SL2

limit switch is a normally open switch connected to battery

negative, the switch closing enables speed limit.

Range

0% to 100% battery volts

Setting

0 to 255

Resolution

0.375 volts per set unit

Example: Setting of 50=18.75 volts

FUNCTION 50:

MODE 1 - SPEED LIMIT 3 (SL3)

(Push CONT 3)

This function allows for the adjustment of the speed limit

(maximum battery volts to the motor) when the SL3 limit

Note: The following functions have function numbers

larger than the numbers on the Handset keyboard. To
access these functions, push the CONT key and the
number shown in the following instructions at the same
time. THE KEY SWITCH MUST BE CLOSED.